1.
Medicina (Kaunas) ; 60(4)2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38674258

RESUMEN

Background and Objectives: The European Kidney Function Consortium (EKFC) equation has been newly proposed for estimating glomerular filtration rate (eGFR) across the spectrum of age. We compared the EKFC equation with the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations in a large-scale Korean population. Materials and Methods: Using the representative Korean health examination data, the Korea National Health and Nutrition Examination Survey (KNHANES 2008-2021), the records of 91,928 subjects (including 9917 children) were analyzed. We compared the EKFC equation with CKiD, CKD-EPI 2009, and CKD-EPI 2021 equations and investigated their agreement across GFR categories. Results: In the total population, the CKD-EPI 2021 equation yielded the highest eGFR value, followed by the CKD-EPI 2009 and EKFC equations. In children, the distribution of eGFR differed significantly between the EKFC and CKiD equations (p < 0.001), with a wider range of eGFR values found with the CKiD equation. Each equation showed weak or moderate agreement on the frequency of the GFR category (κ = 0.54 between EKFC and CKD-EPI 2021; κ = 0.77 between EKFC and CKD-EPI 2009). The eGFR values found by the EKFC equation showed high or very high correlations with those by the CKiD, CKD-EPI 2009, and CKD-EPI 2021 equations (r = 0.85, 0.97, and 0.97, respectively). As eGFR values increased, bigger differences were observed between equations. Conclusions: This large-scale study demonstrates that the EKFC equation would be applicable across the entire age spectrum in Asian populations. It also underscores that national kidney health would be highly affected by an eGFR equation being implemented. Additional investigation and more caution would be warranted for the transition of eGFR equations.


Asunto(s)
Tasa de Filtración Glomerular , Encuestas Nutricionales , Insuficiencia Renal Crónica , Humanos , República de Corea/epidemiología , Masculino , Femenino , Insuficiencia Renal Crónica/fisiopatología , Insuficiencia Renal Crónica/epidemiología , Niño , Adulto , Persona de Mediana Edad , Adolescente , Anciano , Pruebas de Función Renal/métodos , Pruebas de Función Renal/estadística & datos numéricos , Pruebas de Función Renal/normas , Preescolar , Adulto Joven
2.
Diagnostics (Basel) ; 14(6)2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38535013

RESUMEN

BACKGROUND: Few studies have evaluated digital morphology (DM) analyzers on body fluids (BF). We evaluated the performance of a DM analyzer, Sysmex DI-60 (Sysmex, Kobe, Japan) for white blood cell (WBC) differentials in BF samples. METHODS: In five BF samples (two pleural fluids and three ascites) containing a single, dominant cell type (>80%, neutrophils, lymphocytes, macrophages, abnormal lymphocytes, and malignant cells in each sample), we evaluated the precision of the DI-60 and compared the WBC differentials and turnaround times (TAT) between DI-60 and manual counting. RESULTS: The precision of the DI-60 pre-classification and verification was excellent (%CV, 0.01-3.16%). After verification, the DI-60 showed high sensitivity, specificity, and efficiency (ranges: 90.8-98.1%, 96.8-97.9%, and 92.5-98.0%, respectively) for the dominant cell types in neutrophil- and lymphocyte-dominant samples. For all samples, the DI-60 and manual counting showed high correlations for major cell types (neutrophils, lymphocytes, macrophages, and others, r = 0.72 to 0.94) after verification. The agreement between the pre-classification and verification of the DI-60 was strong in the neutrophil-dominant sample (κ = 0.81). The DI-60 showed a significantly longer TAT (min: s) than manual counting for all samples (median TAT/slide: 6:28 vs. 1:53, p < 0.0001), with remarkable differences in abnormal lymphocyte- and malignant cell-dominant samples (21:05 vs. 2:06; 12:34 vs. 2:25). CONCLUSIONS: The DI-60 may provide reliable data in neutrophil- and lymphocyte-dominant BF samples. However, it may require longer times and higher workloads for WBC differentials especially in BF samples containing atypical cells. Further improvement would be needed before applying DM analyzers for routine clinical practice in BF analysis.

3.
Am J Clin Pathol ; 161(2): 111-114, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37852281

RESUMEN

OBJECTIVES: Identification of DNT, a rare partial D, can be challenging, as it is difficult to distinguish from D+. This study aimed to identify DNT individuals by analyzing the DNT proband's family members, characterize DNT, and propose management strategies. METHODS: Family members of the first Korean DNT proband were recruited. RHD genotyping was conducted, and weak D tests were carried out using several anti-D reagents. RESULTS: Three DNT individuals were identified among 6 family members, including 1 with an anti-D alloantibody. As DNT red cells exhibited strong reactivity with all anti-D clones, DNT was serologically indistinguishable from D+. Moreover, unusual serologic findings in DNT individuals only became apparent after anti-D alloimmunization. CONCLUSIONS: We recommend DNT individuals as candidates for Rh immune globulin prophylaxis during the perinatal period and transfusions with D- blood components. An anticipatory RHD genotyping is suggested for partial D family members to prevent potential partial D individuals from becoming alloimmunized.


Asunto(s)
Sistema del Grupo Sanguíneo Rh-Hr , Globulina Inmune rho(D) , Embarazo , Femenino , Humanos , Genotipo , Sistema del Grupo Sanguíneo Rh-Hr/genética , República de Corea
4.
Clin Chem Lab Med ; 62(5): 958-966, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38000045

RESUMEN

OBJECTIVES: White blood cell (WBC)-related flags are essential for detecting abnormal cells including blasts in automated hematology analyzers (AHAs). Cell population data (CPD) may characterize each WBC population, and customized CPD rules can be also useful for detecting blasts. We evaluated the performance of WBC-related flags, customized CPD rules, and their combination for detecting blasts on the Beckman Coulter DxH 900 AHA (DxH 900, Beckman Coulter, Miami, Florida, USA). METHODS: In a total of 239 samples from patients with hematologic diseases, complete blood count on DxH 900 and manual slide review (MSR) were conducted. The sensitivity, specificity, and efficiency of the five WBC-related flags, nine customized CPD rules, and their combination were evaluated for detecting blasts, in comparison with MSR. RESULTS: Blasts were detected by MSR in 40 out of 239 (16.7 %) samples. The combination of flags and CPD rules showed the highest sensitivity compared with each of flags and CPD rules for detecting blasts (97.5 vs. 72.5 % vs. 92.5 %). Compared with any flag, the combination of flags and CPD rules significantly reduced false-negative samples from 11 to one for detecting blasts (27.5 vs. 2.5 %, p=0.002). CONCLUSIONS: This is the first study that evaluated the performance of both flags and CPD rules on DxH 900. The customized CPD rules as well as the combination of flags and CPD rules outperformed WBC-related flags for detecting blasts on DxH 900. The customized CPD rules can play a complementary role for improving the capability of blast detection on DxH 900.


Asunto(s)
Enfermedades Hematológicas , Hematología , Humanos , Recuento de Células Sanguíneas , Enfermedades Hematológicas/diagnóstico , Leucocitos , Recuento de Leucocitos
5.
Diagnostics (Basel) ; 13(14)2023 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-37510116

RESUMEN

We explored the utility of novel biomarkers, presepsin and interferon-λ3 (IFN-λ3), for predicting disease severity and clinical outcomes in hospitalized Coronavirus (COVID-19) patients. In a total of 55 patients (non-critical, n = 16; critical, n = 39), presepsin and IFN-λ3 were compared with sequential organ failure assessment (SOFA) scores and age. Disease severity and clinical outcomes (in-hospital mortality, intensive care unit admission, ventilator use, and kidney replacement therapy) were analyzed using receiver operating characteristic (ROC) curves. In-hospital mortality was also analyzed using the Kaplan-Meier method with hazard ratios (HR). SOFA scores, age, presepsin, and IFN-λ3 predicted disease severity comparably (area under the curve [AUC], 0.67-0.73). SOFA score and IFN-λ3 predicted clinical outcomes comparably (AUC, 0.68-0.88 and 0.66-0.74, respectively). Presepsin predicted in-hospital mortality (AUC = 0.74). The combination of presepsin and IFN-λ3 showed a higher mortality risk than SOFA score or age (HR [95% confidence interval, CI], 6.7 [1.8-24.1]; 3.6 [1.1-12.1]; 2.8 [0.8-9.6], respectively) and mortality rate further increased when presepsin and IFN-λ3 were added to SOFA scores or age (8.5 [6.8-24.6], 4.2 [0.9-20.6], respectively). In the elderly (≥65 years), in-hospital mortality rate was significantly higher when both presepsin and IFN-λ3 levels increased than when either one or no biomarker level increased (88.9% vs. 14.3%, p < 0.001). Presepsin and IFN-λ3 predicted disease severity and clinical outcomes in hospitalized COVID-19 patients. Both biomarkers, whether alone or added to the clinical assessment, could be useful for managing COVID-19 patients, especially the elderly.

6.
Clin Chem Lab Med ; 61(10): 1858-1866, 2023 09 26.
Artículo en Inglés | MEDLINE | ID: mdl-37084402

RESUMEN

OBJECTIVES: The EasyCell assistant (Medica, Bedford, MA, USA) is one of the state-of-the-art digital morphology analyzers. We explored the performance of EasyCell assistant in comparison with manual microscopic review and Pentra DX Nexus (Horiba ABX Diagnostics, Montpellier, France). METHODS: In a total of 225 samples (100 normal and 125 abnormal samples), white blood cell (WBC) differentials and platelet (PLT) count estimation by EasyCell assistant were compared with the results by manual microscopic review and Pentra DX Nexus. The manual microscopic review was performed according to the Clinical and Laboratory Standards Institute guidelines (H20-A2). RESULTS: WBC differentials between pre-classification by EasyCell assistant and manual counting showed moderate correlations for neutrophils (r=0.58), lymphocytes (r=0.69), and eosinophils (r=0.51) in all samples. After user verification, they showed mostly high to very high correlations for neutrophils (r=0.74), lymphocytes (r=0.78), eosinophils (r=0.88), and other cells (r=0.91). PLT count by EasyCell assistant highly correlated with that by Pentra DX Nexus (r=0.82). CONCLUSIONS: The performance of EasyCell assistant for WBC differentials and PLT count seems to be acceptable even in abnormal samples with improvement after user verification. The EasyCell assistant, with its reliable performance on WBC differentials and PLT count, would help optimize the workflow of hematology laboratories with reduced workload of manual microscopic review.


Asunto(s)
Hematología , Humanos , Hematología/métodos , Leucocitos , Linfocitos , Recuento de Plaquetas , Laboratorios , Recuento de Leucocitos , Reproducibilidad de los Resultados
8.
J Clin Med ; 12(2)2023 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-36675387

RESUMEN

ABO incompatibility is not considered a contraindication for hematopoietic stem cell transplantation (HSCT). We hypothesized that recipient-derived isoagglutinin (RDI) levels could play a critical role in clinical outcomes. In this study, we compared clinical outcomes such as survival, GVHD, infection, relapse, transfusion, and engraftment, among ABO-compatible patients (ABOc), ABO-incompatible patients (ABOi) with low RDI, and ABOi patients with high RDI. The ABOi with high RDI group was defined as recipients with more than 1:16 RDI levels. We analyzed 103 recipients (ABOc, 53; ABOi with low RDI, 36; ABOi with high RDI, 14). The ABOi with high RDI group showed a decreased 1-year survival and increased acute GVHD grade IV and RBC transfusion (p = 0.017, 0.027, and 0.032, respectively). The ABOi with high RDI group was an independent risk factor for increased death, RBC transfusion, and poor platelet (PLT) engraftment (odds ratio (OR) = 3.20, p = 0.01; OR = 8.28, p = 0.02; OR = 0.18, p = 0.03, respectively). The ABOi with high RDI group showed significantly delayed PLT engraftment. In conclusion, this is the first study underscoring high RDI levels as a marker predicting unfavorable outcomes in ABOi HSCT.

9.
Clin Chem Lab Med ; 61(1): 133-141, 2023 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-36306547

RESUMEN

OBJECTIVES: CellaVision DC-1 (DC-1, Sysmex, Kobe, Japan) is a newly launched digital morphology analyzer that was developed mainly for small to medium-volume laboratories. We evaluated the precision, qualitative performance, comparison of cell counts between DC-1 and manual counting, and turnaround time (TAT) of DC-1. METHODS: Using five peripheral blood smear (PBS) slides spanning normal white blood cell (WBC) range, precision and qualitative performance of DC-1 were evaluated according to the Clinical and Laboratory Standards Institute (CLSI) EP15-A3, EP15-Ed3-IG1, and EP12-A2 guidelines. Cell counts of DC-1 and manual counting were compared according to the CLSI EP 09C-ED3 guidelines, and TAT of DC-1 was also compared with TAT of manual counting. RESULTS: DC-1 showed excellent precision (%CV, 0.0-3.5%), high specificity (98.9-100.0%), and high negative predictive value (98.4-100.0%) in 18 cell classes (12 WBC classes and six non-WBC classes). However, DC-1 showed 0% of positive predictive value in seven cell classes (metamyelocytes, myelocytes, promyelocytes, blasts, plasma cells, nucleated red blood cells, and unidentified). The largest absolute mean differences (%) of DC-1 vs. manual counting was 2.74. Total TAT (min:s) was comparable between DC-1 (8:55) and manual counting (8:55). CONCLUSIONS: This is the first study that comprehensively evaluated the performance of DC-1 including its TAT. DC-1 has a reliable performance that can be used in small to medium-volume laboratories for assisting PBS review. However, DC-1 may make unnecessary workload for cell verification in some cell classes.


Asunto(s)
Leucocitos , Humanos , Recuento de Leucocitos , Recuento de Células Sanguíneas , Recuento de Eritrocitos , Valores de Referencia , Reproducibilidad de los Resultados
10.
Metabolites ; 12(11)2022 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-36355169

RESUMEN

Adiponectin and high-density lipoprotein cholesterol (HDL-C) are negative predictors for cardio-metabolic disorders. This study explored adiponectin's role in predicting multiple metabolic syndrome components (multi-MetSC) in subjects with extremely high HDL-C levels overall and by sex. We enrolled adults with extremely high HDL-C levels (≥90 mg/dL) in general health checkups and compared adiponectin levels in subjects with and without multi-MetSC. Among 274 subjects (median 44 years, female 79.6%), 19 (6.9%) had a multi-MetSC. The adiponectin level was significantly lower in subjects with multi-MetSC than without (females: 9.2 [6.2-13.3] vs. 12.0 [9.7-15.9] µg/mL, p = 0.039; males: 6.9 ± 2.4 vs. 10.0 ± 5.2 µg/mL, p = 0.013). The optimal cutoff values to predict multi-MetSC were 9.7 µg/mL (sensitivity 64%, specificity 74%) in females and 9.6 µg/mL (sensitivity 100%, specificity 44%) in males. Compared with the high adiponectin group, the low group revealed higher fasting glucose in females and higher waist circumference, visceral fat area, and HDL-C levels in males. Multiple logistic regression analysis confirmed adiponectin as an independent predictor of multi-MetSC (OR 0.85, 95% CI 0.71-0.97). Adiponectin could be a potential biomarker for multi-MetSC in general health checkup subjects with extremely high HDL-C levels. There were sex differences in the metabolic risk factors between low and high adiponectin groups.

11.
Diagnostics (Basel) ; 12(9)2022 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-36140614

RESUMEN

Presepsin is an early indicator of infection, and Krebs von den Lungen 6 (KL-6) and Surfactant Protein A (SP-A) are related to the pathogenesis of pulmonary infection and fibrosis. This study aimed to establish reference intervals (RIs) of presepsin, KL-6, and SP-A levels and to evaluate the possible influence of neonatal and maternal factors on presepsin, KL-6, and SP-A levels in umbilical cord blood (UCB). Among a total of 613 UCB samples, the outliers were removed. The RIs for presepsin, KL-6, and SP-A levels were defined using non-parametric percentile methods according to the Clinical and Laboratory Standards Institute guidelines (EP28-A3C). These levels were analyzed according to neonatal and maternal factors: neonatal sex, gestational age (GA), birth weight (BW), Apgar score, delivery mode, the presence of premature rupture of membranes (PROM), gestational diabetes mellitus (GDM), and pre-eclampsia. Presepsin, KL-6, and SP-A levels showed non-parametric distributions and left-skewed histograms. The RIs of presepsin, KL-6, and SP-A levels were 64.9-428.3 pg/mL, 43.0-172.0 U/mL, and 2.1-36.1 ng/mL, respectively. Presepsin, KL-6, and SP-A levels did not show significant differences according to sex, GA, BW, Apgar score, delivery mode, PROM, GDM, and pre-eclampsia. The median level and 97.5th centile RI of KL-6 showed a slight increase with increased GA. We established RIs for presepsin, KL-6, and SP-A levels in large-scaled UCB samples. Further investigation would be needed to determine the clinical significance.

12.
J Clin Med ; 11(15)2022 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-35893414

RESUMEN

The Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation is the most commonly used equation for estimated glomerular filtration rate (eGFR). Recently, the European Kidney Function Consortium (EKFC) announced a full-age spectrum equation, and the CKD-EPI announced the CKD-EPI refit equations (CKD-EPI-R). We compared CKD-EPI, EKFC, and CKD-EPI-R equations in a large-scale Korean population and investigated their potential implications for CKD prevalence. In a total of 106,021 individuals who received annual check-ups from 2018 to 2020, we compared the eGFR equations according to the Clinical and Laboratory Standards Institute guidelines. Weighted kappa (κ) agreement was used to compare the potential implications for CKD prevalence across the equations. The median value of eGFR tended to increase in the order of EKFC, CKD-EPI, and CKD-EPI-R equations (92.4 mL/min/1.73 m2, 96.0 mL/min/1.73 m2, and 100.0 mL/min/1.73 m2, respectively). The EKFC and CKD-EPI-R equations showed a very high correlation of eGFR and good agreement for CKD prevalence with CKD-EPI equation (r = 0.98 and 1.00; κ = 0.80 and 0.82, respectively). Compared with the CKD-EPI equation, the EFKC equation overestimated CKD prevalence (3.5%), and the CKD-EPI-R equation underestimated it (1.5%). This is the first study comparing CKD-EPI, EKFC, and CKD-EPI-R equations simultaneously. The EKFC and CKD-EPI-R equations were statistically interchangeable with CKD-EPI equations in this large-scale Korean population. The transition of eGFR equations, however, would lead to sizable changes in the CKD prevalence. To improve kidney health, in-depth discussion considering various clinical aspects is imperative for the transition of eGFR equations.

13.
Ann Lab Med ; 42(4): 398-405, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35177560

RESUMEN

BACKGROUND: Digital morphology (DM) analyzers are increasingly being used for white blood cell (WBC) differentials. We assessed the laboratory efficiency of the Sysmex DI-60 system (DI-60; Sysmex, Kobe, Japan) in comparison with manual counting in leukopenic samples. METHODS: In total, 40 peripheral blood smear samples were divided into normal, mild leukopenia, moderate leukopenia, and severe leukopenia groups based on WBC count. In each group, the risk and turnaround time (TAT) were compared between DI-60 and manual counting. Risk was determined by failure mode and effect analysis using the risk priority number (RPN) score, and TAT was recorded for the analytical phase. RESULTS: Overall, DI-60 showed a five-fold lower risk (70 vs. 350 RPN) and longer TAT than manual counting. In severe leukopenic samples, DI-60 showed a shorter TAT/slide and a remarkably lower cell count/slide than manual counting. In all samples, the TAT/cell for DI-60 was substantially longer than that for manual counting (DI-60 vs. manual: total, 1.8 vs. 1.0 sec; normal, 1.5 vs. 0.7 sec; mild leukopenia, 1.9 vs. 0.9 sec; moderate leukopenia, 1.8 vs. 1.0 sec; severe leukopenia, 28.8 vs. 19.0 sec). CONCLUSIONS: This is the first comparative assessment of risk and TAT between DI-60 and manual counting in leukopenic samples. DI-60 decreases the laboratory risk and improves patient safety, but requires more time to count fewer cells, especially in severe leukopenic samples. DM analyzers should be applied selectively depending on the WBC count to optimize laboratory efficiency.


Asunto(s)
Leucocitos , Leucopenia , Humanos , Japón , Laboratorios , Recuento de Leucocitos , Leucopenia/diagnóstico
14.
Diagnostics (Basel) ; 11(12)2021 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-34943409

RESUMEN

Digital morphology (DM) analyzers are widely applied in clinical practice. It is necessary to evaluate performances of DM analyzers by focusing on leukopenic samples. We evaluated the analytical performance, including precision, of a Sysmex DI-60 system (Sysmex, Kobe, Japan) on white blood cell (WBC) differentials in leukopenic samples. In a total of 40 peripheral blood smears divided into four groups according to WBC count (normal, mild, moderate, and severe leukopenia; each group n = 10), we evaluated precision of WBC preclassificaiton by DI-60. %coefficients of variation (%CVs) of precision varied for each sample and for each cell class; the fewer cells per slide, the higher %CV. The overall specificity and efficiency were high for all cell classes except plasma cells (95.9-99.9% and 90.0-99.4%, respectively). The largest absolute value of mean difference between DI-60 and manual count in each group was: 10.77, normal; 10.22, mild leukopenia; 19.09, moderate leukopenia; 47.74, severe leukopenia. This is the first study that evaluated the analytical performance of DI-60 on WBC differentials in leukopenic samples as the main subject. DI-60 showed significantly different performance depending on WBC count. DM analyzers should be evaluated separately in leukopenic samples, even if the overall performance was acceptable.

15.
Diagnostics (Basel) ; 12(1)2021 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-35054235

RESUMEN

The performance of platelet (PLT) counting in thrombocytopenic samples is crucial for transfusion decisions. We compared PLT counting and its reproducibility between Mindray BC-6800Plus (BC-6800P, Mindray, Shenzhen, China) and Sysmex XN-9000 (XN, Sysmex, Kobe, Japan), especially focused on thrombocytopenic samples. We analyzed the correlation and agreement of PLT-I channels in both analyzers and BC-6800P PLT-O mode and XN PLT-F channel in 516 samples regarding PLT counts. Ten thrombocytopenic samples (≤2.0 × 109/L by XN PLT-F) were measured 10 times to investigate the reproducibility with the desirable precision criterion, 7.6%. The correlation of BC-6800P PLT-I and XN PLT-I was arranged moderate to very high; but the correlation of BC-6800P PLT-O and XN PLT-F was arranged high to very high. Both BC-6800P PLT-I vs. XN PLT-I and BC-6800P PLT-O vs. XN PLT-F showed very good agreement (κ = 0.93 and κ = 0.94). In 41 discordant samples between BC-6800P PLT-O and XN PLT-F at transfusion thresholds, BC-6800P PLT-O showed higher PLT counts than XN-PLT-F, except the one case. BC-6800P PLT-O exceeded the precision criterion in one of 10 samples; but XN PLT-F exceeded it in six of 10 samples. BC-6800P would be a reliable option for PLT counting in thrombocytopenic samples with good reproducibility.